Construction drawings / SO01 site office

External elevations

SO-A301R0117 October 2026BP-01 / SO01

Fictional training document. Use the edition assigned by your assessor. Not for construction or site access.

SO-A301: External elevations. Complete structured text equivalent follows.
SO-A301 R01, 17 October 2026. A3 at 1:50. Fictional training source; use your assigned edition.

Read the view direction

ElevationViewing direction / page endsOpenings
SouthLooking north; west left, east right. Width 5000.D01 on eastern side; nominal opening 1000 x 2100. High north roof edge is shown dashed beyond the low south edge.
NorthLooking south; east left, west right. Width 5000.W01 towards the west, therefore right-hand part of this elevation; 1800 x 1200.
EastLooking west; south left, north right. Width 3000.W02 centred between local Y900 and Y2100; 1200 x 1200. Roof rises to the right.
WestLooking east; north left, south right. Width 3000.No scheduled opening; roof falls to the right.

Coordinated levels

ReferenceLevel / relationship
FFL100.300.
Door D01 base / head100.300 / 102.400; height 2100.
Windows W01 and W02 sill / head101.200 / 102.400. Sill 900 above FFL, height 1200.
South / north roof edge103.300 / 103.600, respectively 3000 / 3300 above FFL.
Roof rise300 across building depth 3000: 1:10 in this model.

Purpose and limitations

Elevations show external appearance, opening position and vertical relationships. They do not establish room layout, foundation design, connections, wall ties, glazing performance or compliance. Roof edges are flush with wall outside faces in this simplified exercise. EC01 wall cladding and RF01 sheet roof are described in SO-SP01. The fixed-glazing diagonal is only a local graphical glass identifier; operation is established by the schedule.